What are the performance indicators of grout?

2026.11.06

The performance indicators of grout can be divided into five core categories, covering environmental safety, basic physical and chemical properties, physical mechanics, weather and corrosion resistance, and practical scenario adaptation. All indicators have clear national/group standards as the basis for judgment, which can directly help you screen qualified and durable products.

Environmental and safety indicators

This is the bottom line requirement for home decoration material selection, which directly affects indoor air quality:

TVOC/Total Volatile Organic Compounds: The mandatory national standard GB 18583-2008 requires ≤ 100g/L, and the measured value of high-end products can be as low as 10g/L. The lower the value, the better the environmental protection.

Limit of harmful substances: Free formaldehyde ≤ 1.0g/kg, benzene ≤ 5.0g/kg, toluene+xylene ≤ 150g/kg, must comply with the mandatory standard GB 18583, and reject products without CMA testing reports.

Heavy metal limit: meets the requirements of T/CBMF 166-2022 group standard, with no soluble heavy metal precipitation after curing, suitable for families of the elderly and children.

Authoritative certification: French A+indoor air emission certification and FDA food contact level testing are the core reference for high-end environmental protection products.

Basic physical and chemical indicators

Determine the smoothness of construction and the quality of the formed foundation:

Solid content: The basic requirement of the national standard is ≥ 96%, and high-quality products can reach over 99%. High solid content means that the shrinkage rate after curing is extremely low, and it is not easy to cause collapse or hollowing problems.

Dry time: The national standard requires ≤ 4h, and high-end products can be controlled within 1.5h, which can significantly shorten the waiting time for construction and improve construction efficiency.

Sag: The sag should be ≤ 3mm under normal conditions and after high and low temperatures. The measured value of high-quality products is close to 0mm, and there will be no sagging or falling during construction. The facade construction can also be kept flat.

45561dcc77389cddb2932430d7bb3382.png

Physical and mechanical performance indicators

Determine the structural strength and service life of the seam layer:

Shore D hardness: The basic requirement of the national standard is ≥ 55, and high-quality products can reach 66 or above. The higher the hardness, the less likely it is to leave scratches during daily trampling and friction.

Wear resistance: The national standard requires ≤ 40mg (1000g/500r test conditions), and the measured value of high-end products can be as low as 9mg. Long term use will not cause wear through or exposed seams.

Adhesive strength: The national standard requirement for epoxy colored sand is ≥ 5.5MPa, and high-quality products can reach 6.8MPa or above. It is firmly bonded to the gaps of ceramic tiles and is not easily affected by thermal expansion and contraction to fall off.

Flexibility: The national standard requires no cracks under 50mm testing conditions, suitable for underfloor heating environments, able to buffer the stress caused by temperature difference deformation of ceramic tiles, and avoid cracking.

☀️ Weather and corrosion resistance performance indicators

Determine the long-term stability of Meisew in complex environments:

Yellowing resistance performance: Ordinary epoxy is prone to yellowing within 1-2 years, hydrogenated epoxy is not prone to yellowing within 2-3 years, pure polyurea/organosilicon can achieve no significant yellowing for more than 5 years, and high yellowing resistance products must be preferred in strong UV areas such as balconies.

Acid and alkali resistance: Soak in 5% acetic acid and 5% NaOH for 168 hours without foaming, cracking, or discoloration, and can resist the corrosion of daily cleaning agents such as toilet cleaners and dishwashers.

Water resistance: It does not soften or peel off after long-term immersion in water, and is the core basic indicator of wet areas in kitchens and bathrooms, avoiding water seepage and delamination problems after long-term immersion in water.

Practical indicators for scene adaptation

Exclusive performance requirements for different spaces:

Anti mold grade: The highest grade is grade 0 as specified in GB/T 1741-2020, and there is no mold growth after 28 days of high humidity cultivation. It is a necessary indicator for kitchen and bathroom areas.

Pollution resistance: Daily stains such as vinegar, tea, coffee, etc. have no residue after 1 hour of contact, are easy to wipe, have a dense and non staining surface, and will not turn black or dirty even after long-term use.

Cold and hot cycle stability: The retention rate of tensile shear strength after high and low temperature alternation is ≥ 60%, suitable for underfloor heating environment, and the performance does not significantly deteriorate under long-term temperature difference changes.